Home arrow . arrow Loadcell Transmitters arrow Multi-Input Loadcell Transmitter 24/12 VDC
Info: Your browser does not accept cookies. If you want to put products into your cart and purchase them you need to enable cookies.

PDF



View More Images (3)
View More Images (3)

Multi-Input Loadcell Transmitter 24/12 VDC

Code: GB-4L/

Price:  Call for Pricing


:

:

:

:

:

:

Availability

Usually ships in:

1-4w.gif


Four loadcell inputs each with individually isolated outputs as standard.
Up to 32 loadcell inputs can be used. 24 bit input conversion. 12 bit analogue output conversion. Galvanic isolation to 1 000 VDC for all inputs, outputs, auxiliary power supply and communications. Each input has a seperate, isolated output, and two programmable alarm output relays. Two averaged outputs - an isolated 4-20 mA and a simulated loadcell output for direct connection to an existing single loadcell input system. User friendly PC based configuration and calibration. Detailed access of all inputs, outputs and alarm levels via register based RS485 ASCII interface.
Applications:
Can also be used as a remote terminal unit with simple register based ASCII interface.
Four bi-polar differential voltage inputs with programmableinput range (24 bit).
Nine relay outputs.
Five 0/4-20 mA outputs (12 bit).
One 0 to 50 mV loadcell type output (12 bit).
One digital input (0 to 24 VDC).
Control of 10 LEDs.
Specifications:
  • Differential Input with isolated 1.00, 2.50, 5.00 or 10.00 V excitation (20 mA maximum) suited to loadcells/strain gauges.
  • Input ranges: ±20 mV, ±40 mV, ±80 mV, ±160 mV, ±320 mV, ±640 mV, ±1.280 V, ±2.560 V.
  • Analogue output - 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 0 to 10 V, ±5 V and ±10 V (factory configured).
  • Response time input to output – approximately 1 second.
  • One 4-20 mA output for each loadcell input plus summed 4-20 mA output and 0-50 mV simulated loadcell output for existing single input systems.
  • Resolution – 24 bit basic input A to D conversion, 12 bit output resolution.
  • Linearity better than 0.05% of full scale.
  • Two signal relay outputs (24 V at 1 A). Configurable operating sense – normally open or normally closed, adjustable hysteresis and selectable delay on operate. Software latching of switching
    level.
  • Two red LED outputs. Configurable operating sense. Software latching of switching level.
  • RS232 configuration using Danntech Configuration Cable.
  • User friendly software calibration, output scaling, relay and LED operation, configurable zero, full-scale adjustment.
  • Isolated RS485 communications on terminals 15 and 16 as well as the DIN rail plug-in connector.
  • Rear plug-in DIN rail bus connection for power and RS485 communications.
  • RS485 baud rates 9 600, 19 200, 57 600 and 115 200 bits/sec.
  • Galvanic isolation between auxiliary supply, input, output and RS485 communications > 1 000 VDC.
  • 24 VDC (-5%, +10%) auxiliary power supply at approx 400 mA.
  • Operating temperature -10°C to 60°C, storage temperature -20°C to 70°C.
  • DIN rail mounting with plug-in screw terminal connections -4 x 4 per module.
  • Dimensions - 113 x 118 x 112 mm (width x height top to bottom x depth off DIN rail).