GB-SHH-Specifications

  • Input options are 0 to 10 V, 0 to 5 V, ±10 V, 0 to 20 mA, 4 to 20 mA, resistance (potentiometer).
  • Output options are 0 to 10 V, ±10V (up to 1330 mA),
    current output up to ± 1330 mA.
  • Requires an external DC supply of either: 9 to 18 VDC (12 VDC nominal),
    18 to 36 VDC (24 VDC nominal), 36 to 75 VDC (48 VDC nominal).
  • Supply current typically Iout + 100 mA.
  • Isolation of up to 1500 VDC or more, between input, output and the auxiliary power supply.
  • Bias (zero), Ramping and Imax (span) adjustments.
  • Ramping selectable in three ranges 0-10 sec, 0-60 sec and 0-120 sec - DIP switch selectable with fastest step response of 10 mS or less.
  • Front panel adjustments can be set as needed and
    then disabled using a DIP switch.
  • Optional RS485 communications with our simple command interface so multiple units can be used with remote control.
  • Modbus communications option in development. Hydraulic valve controller option available on request with dither and ramping.
  • One isolated digital input.
  • Internal output isolation relay.
  • Heatsink temperature monitoring with automatic shutdown at 80°C and restart at 70°C.
  • Operating temperature -10°C to 60°C.
  • Input/output accuracy better than 0.5%.
  • DIN rail mounting.
  • Plug-in screw terminal connections.
  • Dimensions 40 x 110 x 113 mm (width x length top to bottom x height off DIN rail).
  • Approximate weight 150 g.