      The Loadcell transmitter is designed for use with the most common strain gauge loadcells. These loadcells transmitters are robust, accurate, versatile, and cost-effective, making them ideal for industrial applications. Our loadcell transmitter is designed to be the ideal "best-value" converter for PLCs and other applications.

      Loadcell Transmitter Functional Diagram

      Specifications
      • Loadcell/Strain Gauge/Wheatstone Bridge Input.
      • Selectable Input Ranges (DIP switch selectable)- 0 - 10 mV; ±10 mV; 0 - 20 mV; ±20 mV; 0 - 30 mV; ±30 mV; 0 - 100 mV; ±100 mV.
      • High quality, stable input instrumentation amplifier 16 bit conversion.
      • Input impedance > 10 MΩ.
      • Accuracy better than 0.05 % of full scale.
      • Resolution better than 0.03% of range.
      • Temperature stability less than 0.1% over the temperature range 20°C to 50°C, i.e. 0.004% per °C.
      • Selectable process signal outputs (DIP switch selectable) - 4-20 mA, 0-20 mA, 0-10 V, ±10 V, 0-5 V.
      • Maximum load resistance 400 Ω for current outputs.
      • Voltage output current maximum is 5 mA.
      • Input and outputs - ±10% over and under range.
      • Step response < 320 mSec with filtering off. 
      • Trimpot adjustment of zero and span the output.
      • Auxiliary power supply 9 to 36 VDC at approximately 100 mA or mains supply 85 to 260 VAC.
      • Galvanic isolation between auxiliary supply, input and all outputs > 1000 VDC.
      • Power On/Status green LED, Output Status and Alarm LEDs.
      • Input zero/tare and span capture using front panel push button switches which can be disabled.
      • Configurable alarm relay.
      • Optional Modbus RTU and Danntech RMF protocol with a comprehensive register access.
      • Internal temperature monitoring.
      • Excitation voltage monitoring.
      • Optional additional auxiliary analogue input.
      • Excitation for one loadcell, multiple loadcells can be used with our auxiliary 10 V 400 mA power supply.
      • Operating temperature -10°C to +70°C.
      • High quality plug-in screw terminals.
      • High quality, self-extinguishing polyamide enclosure.
      • DIN rail mounting enclosure - 22.5 x 100 x 113 mm (width x length top to bottom x height off DIN rail).
      • Approximate weight 100 g.
      Documentation
      Applications
      • Can be used with most common strain gauge loadcells
      • High Speed Strain Gauge Amplifier/Isolator